This pressure sensor is designed for operation in a vented gage configuration, with a pressure range of 0 to 500 psi. It has a minimum operating temperature of -30°C and a maximum operating temperature of 90°C. The sensor is rated for use with a typical operating supply voltage of 15, 18, or 24 volts, and has a maximum operating supply voltage of 28 volts. It features a 1/4" port size and is electrically terminated with Jupiter TP connectors. The sensor is also rated for use in harsh environments, with an IP68 rating for protection against solid particles and water.
| Media |
Gas |
| IP Rating |
IP68 |
| Pin Count |
2 |
| Port Size |
1/4 |
| RoHS Version |
2002/95/EC |
| Device Pressure Type |
Vented Gage |
| Electrical Termination |
Jupiter TP |
| Operating Pressure Range |
0psi to 500psi |
| Max Operating Temperature |
90°C |
| Min Operating Temperature |
-30°C |
| Max Operating Supply Voltage |
28V |
| Min Operating Supply Voltage |
12V |
| Typical Operating Supply Voltage |
15|18|24V |