This pressure sensor is designed for use in environments with operating pressures ranging from 0 to 3000psi. It is a vented gage device, suitable for applications where pressure is measured relative to atmospheric pressure. The sensor operates within a temperature range of -30 to 90 degrees Celsius and can be supplied with voltages between 12 and 28 volts. The device features a 1/4 inch port size and is electrically terminated with Jupiter TP connectors, providing an IP68 rating for use in harsh environments.
| Media |
Gas |
| IP Rating |
IP68 |
| Pin Count |
2 |
| Port Size |
1/4 |
| RoHS Version |
2002/95/EC |
| Device Pressure Type |
Vented Gage |
| Electrical Termination |
Jupiter TP |
| Operating Pressure Range |
0psi to 3000psi |
| Max Operating Temperature |
90°C |
| Min Operating Temperature |
-30°C |
| Max Operating Supply Voltage |
28V |
| Min Operating Supply Voltage |
12V |
| Typical Operating Supply Voltage |
15|18|24V |