ZSE30A-01-F-MGY
Дополнительная информация
| RoHS | Compliant |
| Ul/csa | E216656 |
| Ce/ukca | Marked |
| Display | 4-digit, 7-segment, 2-color LCD, red/green |
| Standards | CE/UKCA marking, UL/CSA E216656, RoHS |
| Piping port | R1/8 with M5 female thread |
| Analog output | 4 to 20 ±2.5% F.S.mA |
| Pressure type | Vacuum pressure |
| Response time | 2.5 or less; anti-chattering selectable 20, 100, 500, 1000, 2000ms |
| Switch output | PNP open collector 1 output |
| Applicable fluid | Air, non-corrosive gas, non-flammable gas |
| Display accuracy | ±2% F.S. ±1 digit at 25 ±3°C |
| Enclosure rating | IP40 |
| Lead wire option | Lead wire with connector, 2 m, with connector cover |
| Residual voltage | 1 or less at 80 mA load currentV |
| Unit specification | Fixed SI unit |
| Withstand pressure | 500kPa |
| Current consumption | 40 or lessmA |
| Maximum load current | 80mA |
| Minimum unit setting | 0.1kPa |
| Power supply voltage | 12 to 24 ±10%, ripple 10% or lessVDC |
| Rated pressure range | 0.0 to -101.0kPa |
| Analog output linearity | ±1% F.S. |
| Operating humidity range | 35 to 85, no condensation%RH |
| Short circuit protection | Yes |
| Display/set pressure range | 10.0 to -105.0kPa |
| Operating temperature range | 0 to 50, no freezing or condensation°C |
| Analog current output load impedance | 50 minimum; 300 maximum at 12 V; 600 maximum at 24 Vohm |