TIB 120-124
Дополнительная информация
| MTBF | 1450000h |
| RoHS | Compliant with exemptions 7(a), 7(c)-I |
| Scip | 2ba6277d-1bef-4c1b-aabf-928b69d91b71 |
| REACH | SVHC list compliant; Annex XVII compliant |
| Safety | IEC/EN/UL 62368-1, IEC/EN/UL 61010-1, UL 508 |
| Weight | 461g |
| Dimensions | 114.2 x 36 x 124.2mm |
| Efficiency | 94 typ.% |
| Output Power | 120W |
| Mounting Type | DIN-Rail Mount |
| Output Current | 5A |
| Output Voltage | 24VDC |
| Connection Type | Screw Terminal |
| Input Frequency | 45-65Hz |
| AC Input Voltage | 85-264VAC |
| DC Input Voltage | 90-350VDC |
| Ripple and Noise | 100 max.mVp-p |
| Safety Approvals | EN 62368-1, IEC 62368-1, UL 62368-1, UL 508, EN/IEC/UL 61010-1 |
| Peak Output Current | 7.5A |
| Operating Temperature | -40 to +70°C |
| Power Factor at 115 VAC | 0.97 min. |
| No Load Power Consumption | 3200 max.mW |
| Output Voltage Adjustment | 23.5-28.0VDC |
| Isolation Test Voltage Input to Output | 3000VAC |
Если у вас не открывается документ, нажмите, чтобы открыть файл в новой вкладке.